SPECIFICATION RT-510 ISSUE 12
Page 3
4.3.1
Dimensions and Longitudinal Change
Three 6 inch (150 mm) specimens of tubing, as supplied, shall be measured for length ± 1/32 inch
(± 1 mm) and inside diameter in accordance with ASTM D2671, conditioned for 10 minutes in a
175 ± 5°C (347 ± 9°F ) oven, cooled to 23 ± 3°C (73 ± 5°F) and then re-measured. Prior to and after
conditioning, the dimensions of the tubing shall be in accordance with Table 1 and the longitudinal change
shall be in accordance with Table 3. Longitudinal change shall be calculated as follows:
C =
L1 - L0
L0
x 100
Where:
C
L0
L1
=
=
=
Longitudinal Change [Percent]
Length Before Conditioning [inches (mm)]
Length After Conditioning [inches (mm)]
4.3.2
4.3.3
4.4
5.0
5.1
5.2
Tensile Strength, Tensile Stress and Ultimate Elongation
Test three specimens of tubing for tensile strength and ultimate elongation in accordance with
ASTM D2671 and for tensile stress in accordance with ASTM D412.
The rate of jaw separation shall be 20 ± 2 inches (500 ± 50 mm) per minute.
Copper Stability
Three 6 inch (150 mm) specimens of tubing shall be slid over snug fitting, straight, clean, bare copper
mandrels, either solid or tubular. The specimens on the mandrels shall be conditioned for 24 hours in a
desiccator or similar humidity chamber at 90 to 95 percent relative humidity and 25 ± 3°C (77 ± 5°F) . The
specimens on the mandrels then shall be conditioned for 168 hours in a 121 ± 2°C (250 ± 4°F) oven. After
conditioning, the specimens shall be removed from the oven, cooled to 23 ± 3°C (73 ± 5°F) . The copper
mandrels shall then be removed from the tubing, then the tubing and copper mandrels shall be examined.
Darkening of the copper due to normal air oxidation shall not be cause for rejection. The tubing shall be
tested for Ultimate Elongation in accordance with 4.3.2.
Rejection And Retest
Failure of any sample of tubing to comply with any one of the requirements of this specification shall be
cause for rejection of the lot represented. Tubing which has been rejected may be replaced or reworked to
correct the defect and then resubmitted for acceptance. Before resubmitting, full particulars concerning the
rejection and the action taken to correct the defect shall be furnished to the inspector.
Preparation for Delivery
Packaging
Packaging shall be in accordance with good commercial practice. The shipping container shall be not be
less than 125 pound-test fiberboard.
Marking
Each container of tubing shall be permanently and legibly marked with the size, quantity, manufacturer's
identification and lot number.
If this document is printed it becomes uncontrolled. Check for the latest revision.
? 2005-2010 Tyco Electronics Corporation. All rights reserved
相关PDF资料
NT-MIL-3-0-SP HEAT SHRINK TUBING
NTD2425-10 RELAY SSR AC OUT 240VAC 25A PNL
NUD4001DEVB EVAL BOARD FOR NUD4001D
NXN1.75GN NOMEX SLEEVING 1 3/4" GREEN 100'
NY PMS 102 0050 PH SCREW MACH PHIL 10-32X1/2 NYLON
FX2C1-68P-1.27DSAL(71) 板对板与夹层连接器 68P STRAIGHT HEADER T/H NO CLN PCB LK CL
OAA160PTR RELAY OPTOMOS 50MA DP-NO 8FLTPK
OAA160S RELAY OPTOMOS 50MA DP-NO 8-SMD
相关代理商/技术参数
NT-3/8-0-SP 功能描述:热收缩管和套管 HS-TUBING .375" BK PRICE PER FT RoHS:否 制造商:3M Electronic Specialty 类型:Tubing 材料:Polyolefin, Flexible 颜色:Clear 最低收缩温度:+ 100 C 恢复直径: 长度:100 ft 内径:1.5 in 收缩率:2:1
NT-3/8-0-SP-CS5002 制造商:TE Connectivity 功能描述:NT-3/8-0-SP-CS5002
NT-3/8-0-SP-CS5338 制造商:TE Connectivity 功能描述:NT-3/8-0-SP-CS5338
NT-3/8-0-SP-CS6327 制造商:TE Connectivity 功能描述:NT-3/8-0-SP-CS6327
NT-3/8-0-SPCUT 76MM 制造商:TE Connectivity 功能描述:NT-3/8-0-SP
NT300 制造商:LUMINIS 制造商全称:LUMINIS 功能描述:Wall mount
NT302MI 制造商:未知厂家 制造商全称:未知厂家 功能描述:FREQUENCY-TO-DIGITAL CONVERTER
NT-306 制造商:Pro'skit 功能描述:Volatage Detector